聯(lián)系 - 熱線
氣源沒化驗就開機,后期停機單比電費還厚
很多電站前期把預(yù)算全砸在主機上,結(jié)果跑起來三個月就開始掉功率、火花塞成批燒。拆開看,缸內(nèi)沒有大傷,問題出在“氣”這一頭——機組只是背了鍋。
Many power plants spend all their budget on the main engine in the early stage, but as a result, they start to lose power and spark plugs burn out in batches after running for three months. Upon opening, there are no major injuries inside the cylinder, but the problem lies in the "gas" side - the unit is just taking the blame.

燃?xì)鈾C不是萬能 burner,每一種氣都要單獨對曲線。管道天然氣要求甲烷七成以上、壓力穩(wěn)定在80到200kPa,前處理重點在脫水和調(diào)壓;沼氣填埋氣甲烷通常四成上下,硫化氫必須壓到200毫克以下,雙級脫硫加氣水分離不能省;低濃瓦斯甲烷門檻九個點,氧含量必須受控,阻火加穩(wěn)壓加濃度監(jiān)測三件套缺一不可;焦?fàn)t煉化尾氣含氫高還帶焦油萘,降溫除焦油除塵一步都不能跳。
A gas engine is not a universal burner, and each type of gas needs to be individually tested for its curve. Pipeline natural gas requires more than 70% methane and a stable pressure of 80 to 200kPa, with a focus on dehydration and pressure regulation for pre-treatment; Methane in biogas landfill gas is usually around 40%, and hydrogen sulfide must be compressed to below 200 milligrams. The separation of two-stage desulfurization and gas injection water cannot be saved; There are nine threshold points for methane in low concentration gas, and the oxygen content must be controlled. The three piece set of fire prevention, pressure stabilization, and concentration monitoring is indispensable; The tail gas from coke oven refining has high hydrogen content and tar naphthalene, so the cooling, tar removal, and dust removal steps cannot be skipped.
現(xiàn)場最容易被砍掉的正是前處理三件套:穩(wěn)壓罐、脫硫塔、精細(xì)過濾。氣壓波動超過每分鐘1kPa,空燃比再聰明的系統(tǒng)也追不上;硫化氫不脫硫,機油酸值兩周就超標(biāo);焦油進(jìn)缸,火花塞和進(jìn)氣道一個月積一層黑殼。
The most easily cut off set on site is the pre-treatment three piece set: pressure stabilizing tank, desulfurization tower, and fine filtration. The pressure fluctuation exceeds 1kPa per minute, and even the smartest system in terms of air-fuel ratio cannot catch up; Hydrogen sulfide does not desulfurize, and the oleic acid value exceeds the standard within two weeks; Tar enters the cylinder, and the spark plug and intake duct accumulate a layer of black shell every month.
選型時順手核對四件事:拿近期氣樣做全組分報告,別只報“大概沼氣”;額定功率按可用氣量乘連續(xù)運行下限算,別用峰值氣量,長期輕載比滿負(fù)荷更傷機;高氫尾氣必須換富氫燃燒標(biāo)定,普通天然氣曲線直接套會爆震;安全件別省,水封阻火器、濃度監(jiān)測、啟動前自動吹掃,失敗必須關(guān)氣吹掃3到5分鐘再點火。
When selecting, check four things: take a recent gas sample to make a full component report, don't just report "approximate biogas"; The rated power is calculated by multiplying the available gas volume by the lower limit of continuous operation. Do not use peak gas volume, as long-term light load is more damaging to the machine than full load; High hydrogen exhaust gas must be calibrated with rich hydrogen combustion, and directly fitting the curve of ordinary natural gas will cause detonation; Save on safety components, including water sealed flame arresters, concentration monitoring, and automatic blowing before startup. If it fails, turn off the gas and blow for 3 to 5 minutes before ignition.
運維只記兩個動作:每日看燃?xì)鈮翰?,每周校一次甲烷和氧分析儀。這兩個習(xí)慣堅持做,非計劃停機通常能砍掉一半以上。
Operation and maintenance only remember two actions: check the gas pressure difference daily and calibrate the methane and oxygen analyzer once a week. Persist in these two habits, and unplanned downtime can usually cut them in half or more.
把“先化驗、再配路、標(biāo)定跟著氣走”釘在調(diào)試清單里,廢氣變電能這件事才真正開始賺錢。
Only by adding the phrase 'test first, then route and calibrate following the gas' to the debugging checklist can the conversion of waste gas into electricity truly begin to make money.
業(yè)務(wù)分類
Business classification產(chǎn)品推薦
product recommendation聯(lián)系方式
Contact Information
聯(lián)系我們
contact us
公司地址:山東省濟(jì)南市章丘區(qū)龍山街道潘王路24239號(龍山工業(yè)園八號路)
關(guān)注公眾號
企業(yè)二維碼
截屏,微信識別二維碼